  Datasheet File OCR Text:
  digital display (14 mm) m7e new models with blanking function added to the series ? single-color (red or green) and two-color (red or green selectable) displays with a character height of 14 mm are available for a variety of applications and locations. ? miniature design with a 43-mm depth is perfect for saving space in equipment and devices. ? wide-range power supply from 12 to 24 vdc. ? negative sign ( ? ) display with signal codes is possible for decimal-display models. ? models with zero suppression function available. model configuration unit configuration displays +, ?, 1 and . (decimal point). decimal display unit displays 0, 1, 2, .9, and . (decimal point) with a character height of 14.2 mm. displays 0, 1, 2, .9, a, b, f, and . (decimal point) with a character height of 14.2 mm. spacer hexadecimal display unit used to separate displays and to allow space for changes in specifications. available in black and in light gray. displays units with text and symbols (see face plates) with a surface- lighting led. unit display unit facilitates maintenance and inspection. available with soldered terminals or with pcb terminals. connector used for panel mounting. right and left plates form a pair (available as sets only). black or light gray. end plate (right) end plate (left) 1. display unit http://www.ia.omron.com/ 1 (c)copyright omron corporation 2007 all rights reserved.
m7e ordering information list of models accessories (order separately) end plate note: the right and left plates form a pair. spacer connector mother board note: refer to m7e mother board for display units (character height: 14 mm) for details. display contents display color logic model unit red --- m7e-01ur2- @ (see note 3.) note: 1. models with zero suppression are blank only when the display is 0 and the decimal is off by wiring as shown on page 12. 2. models with blanking enable turning off a user-specified display ( 0 to 9 , a to f ) by inputting a signal to the blank input terminal. 3. the symbol in the box ( @ ) indicates the code for the display contents. refer to page 13. green --- m7e-01ug2- @ (see note 3.) display contents display color type model model with zero suppression (see note 1.) model with blanking (see note 2.) 1 red positive --- m7e-01brp2 negative --- m7e-01brn2 dynamic output --- m7e-01brd2 green positive --- m7e-01bgp2 negative --- m7e-01bgn2 dynamic output --- m7e-01bgd2 decimal red positive m7e-01drp2 m7e-01drp2-b negative m7e-01drn2 m7e-01drn2-b dynamic output m7e-01drd2 m7e-01drd2-b green positive m7e-01dgp2 m7e-01dgp2-b negative m7e-01dgn2 m7e-01dgn2-b dynamic output m7e-01dgd2 m7e-01dgd2-b red/green (two colors) negative m7e-01drgn2 m7e-01drgn2-b hexadeci- mal red positive M7E-01HRP2 M7E-01HRP2-b negative m7e-01hrn2 m7e-01hrn2-b green positive m7e-01hgp2 m7e-01hgp2-b negative m7e-01hgn2 m7e-01hgn2-b connectable plcs ? : connectable : not connectable : connectable (see note.) note: connectable but an external resistor is required and only 24 vdc must be supplied. refer to external connections on page 9 and 10 for details. m7e model plc output method display contents type static output dynamic output pnp output npn output 1, decimal positive ? negative ? dynamic output ? hexa- decimal positive ? negative ? unit --- ? (only voltage imposed) case color item model light gray m7e-012m black m7e-012m-1 case color item model light gray m7e-012pa black m7e-012pa-1 terminal model solder terminal nrt-c solder terminal nrt-cn pcb terminal nrt-cp type number of digits model static 4 m7e-01mb4-s2 static 3 m7e-01mb3-s2 static 2 m7e-01mb2-s2 http://www.ia.omron.com/ 2 (c)copyright omron corporation 2007 all rights reserved.
m7e specifications ratings characteristics note: 1. the above values are initial values. 2. impulse conditions rise time: 1 ns + 10% max. pulse width: 100 ms, 1 p s polarity: positive, negative, asynchronous to power frequency, 100-hz repeat frequency. installation terminal arrangements and functions terminal arrangement note: the circled numbers are the connector pin numbers (nrt- @ ). note: 1. the latch terminal on 1. display units is provided only on dynamic output models. 2. the terminal numbers of the unit display unit are different from the terminal numbers of the connector. rated power supply wide range from 12 to 24 vdc allowable voltage fluctuation range 90% to 110% of rated voltage current consumption (per display unit) red led: 35 ma max. at 24 vdc 60 ma max. at 12 vdc greed led: 40 ma max. at 24 vdc 75 ma max. at 12 vdc red/green led: 45 ma max. at 24 vdc 90 ma max. at 12 vdc input level positive logic high: 9.6 v to power supply voltage low: 0 to 3 v negative logic high: 4 v to power supply voltage low: 0 to 1.5 v dynamic output high: 4 v to power supply voltage low: 0 to 1.5 v ambient temperature operating: 10q c to 55q c (with no icing) storage: 25q c to 70 q c (with no icing) ambient humidity operating: 35% to 85% (with no condensation) insulation resistance 100 m : min. at 500 vdc (between each terminal and mounting panel) dielectric strength 500 vac at 50/60 hz for 1 minute (between each terminal and mounting panel) noise immunity (see note 2.) power terminal: r 500 v input terminal: r 500 v (normal mode) r 1,500 v (common mode) vibration resistance destruction: 10 to 55 hz, 0.75-mm double amplitude shock resistance destruction: 300 m/s 2 degree of protection iec ip40 (portion on panel surface) compatible connector omron nrt-c/nrt-cn/nrt-cp r 1. display unit decimal/hexadecimal display unit (single color) m7e-01b @@ 2 models with zero suppression m7e-01d @@ 2/m7e-01h @@2 models with blanking m7e-01d @@2-b/m7e-01h@@ 2-b unit display unit decimal display unit (two colors) m7e-01u @ 2- @ models with zero suppression m7e-01drgn2 models with blanking m7e-01drgn2-b power (+) signal input blank input decimal point latch (see note 1.) power (0 v) 1 + ? v k a c d f g h i bi 1 + ? dp le g v bi 1 + ? dp le g k a c d f g h i zero-suppress output power (+) signal input zero-suppress input j e b data a (2 0 ) b (2 1 ) c (2 2 ) d (2 3 ) decimal point latch power (0 v) open v rbo rbi a b c d dp le r/g gnd 11 10 9 8 7 6 5 4 3 2 1 k a c d f g h i power (+) signal input j e b data a (2 0 ) b (2 1 ) c (2 2 ) d (2 3 ) decimal point latch power (0 v) open v rbo rbi a b c d dp le r/g gnd blank input open 11 10 9 8 7 6 5 4 3 2 1 power (+) power (0 v) v k a g 1 k a c d f g h i zero-suppress output power (+) signal input zero-suppress input j e b data a (2 0 ) b (2 1 ) c (2 2 ) d (2 3 ) decimal point latch power (0 v) v rbo rbi a b c d dp le r/g gnd 11 10 9 8 7 6 5 4 3 2 1 k a c d f g h i power (+) signal input j e b data a (2 0 ) b (2 1 ) c (2 2 ) d (2 3 ) decimal point latch power (0 v) open v rbo rbi a b c d dp le r/g gnd blank input 11 10 9 8 7 6 5 4 3 2 1 color selection input r/g (see note 2.) color selection input r/g http://www.ia.omron.com/ 3 (c)copyright omron corporation 2007 all rights reserved.
m7e terminal functions note: 1. refer to the input code table for rbo and rbi control. 2. applicable to the m7e-01drgn2 and -01drgn2-b only. decimal/hexadecimal display unit (single-color models with zero suppression) decimal/hexadecimal display unit (single-color model with blanking) input codes r 1. display unit positive logic (m7e-01brp2/m7e-01bgp2) note: bi takes precedence over any input signal. * either high or low. negative logic (m7e-01brn2/m7e-01bgn2) note: bi takes precedence over any input signal. * either high or low. unit display unit this display lights when voltage is applied to the power supply terminals (v and g). ter- minal sym- bol name function decimal/hexadecimal display unit r display unit models with zero suppression models with blanking vpower supply positive power supply input terminal rbo control output zero-suppress output (see note 1.) --- --- rbi control input zero-suppress output (see note 1.) blanking input (turns off all the displays including decimal point.) --- bi control input --- --- blanking input (turns off all the displays including decimal point.) a b c d data inputs applicable to decimal/ hexadecimal display unit ? displays a digit or symbol corresponding to the value of the binary code signal. ? decimal display uses 0 to 9; nothing will be displayed for higher values. --- 1 +  data inputs --- --- applicable to r 1. display unit only for each input terminal, the input of a signal causes a display to light. dp data inputs the decimal point lights. le control input latch input the immediately preceding display condition is retained. r/g control input color selection input (see note 2.) set low for green display and high for red display. --- gpower supply 0-v power-supply (ground) input terminal (gnd) a (2 0 ) b (2 1 ) c (2 2 ) d (2 3 ) control output (zero-suppress output) control input (zero-suppress input) nrt- @ connector pin number power supply input (+) data input decimal point input control input (latch input) open power supply input 0 v terminal symbol nrt- @ connector pin number power supply input (+) data input decimal point input control input (latch input) open power supply input 0 v terminal symbol control input (blank input) open models with positive or negative logic input signal display conditions connector pin no. igfhd terminal symbol bi +  1dp input signals lllll blank lhlll llhll lllhl llllh h * * * * blank (see note.) input signal display conditions connector pin no. igfhd terminal symbol bi +  1dp input signals hhhhh blank hlhhh hhlhh hhhlh hhhhl l * * * * blank (see note.) v-g terminals display open circuit blank voltage applied lit http://www.ia.omron.com/ 4 (c)copyright omron corporation 2007 all rights reserved.
m7e decimal/hexadecimal display unit models with zero suppression positive logic (m7e-01drp2/m7e-01dgp2/M7E-01HRP2/ m7e-01hgp2) note: the display will go blank when the data input is "0" and the dp is off. * either high or low negative logic (m7e-01drn2/m7e-01dgn2/m7e- 01drgn2/m7e-01hrn2/m7e-01hgn2) note: the display will go blank when the data input is "0" and the dp is off. * either high or low input out- put display condition connector pin no. cefghd i j terminal number 356784 9 10 terminal symbol le d c b a dp rbi rbo decimal hexadeci- mal input signals llllll l l 0 llllhl * l 1 lllhll * l 2 lllhhl * l 3 llhlll * l 4 llhlhl * l 5 llhhll * l 6 llhhhl * l 7 lhllll * l 8 lhllhl * l 9 lhlhll * l a lhlhhl * l blank b lhhlll * l blank c lhhlhl * l blank d lhhhll * l blank e lhhhhl * l blank f l****h * l * l l l l l h h blank (see note.) h * * * * * * * retains the display conditions of a through d and dp terminals before le goes high. rbi is not related. input out- put display condition connector pin no. cefghd i j terminal number 356784 9 10 terminal symbol le d c b a dp rbi rbo decimal hexadec- imal input signals hhhhhh h h 0 hhhhlh * h 1 hhhlhh * h 2 hhhl lh * h 3 hhlhhh * h 4 hhlhlh * h 5 hhl lhh * h 6 hhl l lh * h 7 hlhhhh * h 8 hlhhlh * h 9 hlhlhh * h a hlhllh * h blank b h l l h h h * h blank c hllhlh * h blank d h l l l h h * h blank e h l l l l h * h blank f h* * * *l * h * h h h h h l l blank (see note.) l * * * * * * * retains the display conditions of a through d, dp and r/g terminals before le goes low. rbi is not related. http://www.ia.omron.com/ 5 (c)copyright omron corporation 2007 all rights reserved.
m7e models with blanking positive logic (m7e-01drp2-b/m7e-01dgp2-b/m7e- 01hrp2-b/m7e-01hgp2-b) note: rbi takes precedence over any input signal. * either high or low negative logic (m7e-01drn2-b/m7e-01dgn2-b/m7e- 01drgn2-b/m7e-01hrn2-b/m7e-01hgn2-b) note: rbi takes precedence over any input signal. * either high or low r 1. display unit (m7e-01brd2/m7e-01bgd2) note: bi takes precedence over any input signal. * either high or low input display condition connector pin no. ciefghd terminal number 3 9 56784 terminal symbol le rbi d c b a dp decimal hexa- decimal input signals l l lllll 0 lllllhl 1 llllhll 2 llllhhl 3 lllhlll 4 l l lhlhl 5 lllhhll 6 lllhhhl 7 llhllll 8 llhllhl 9 l l hlhll a l l h l h h l blank b l l h h l l l blank c l l h h l h l blank d l l h h h l l blank e l l hhhhl blank f *l****h * h * * * * * blank (see note.) h l * * * * * retains the display conditions of a through d terminals before le goes high. dp is not related. input display condition connector pin no. c i efghd terminal number 3956784 terminal symbol le rbi d c b a dp decimal hexa- decimal input signals h h hhhhh 0 hhhhhlh 1 hhhhlhh 2 hhhhllh 3 hhhlhhh 4 hhhlhlh 5 hhhllhh 6 hhhlllh 7 hhlhhhh 8 hhlhhlh 9 h h lhlhh a hhlhllh blank b hhllhhh blank c hhllhlh blank d hhlllhh blank e h h llllh blank f *h****l * l * * * * * blank (see note.) l h * * * * * retains the display conditions of a through d, and r/g terminals before le goes low. dp is not related. models with dynamic outputs input display condition connector pin no. cigfhd terminal symbol le bi +  1dp input signals lhlllh blank lhhllh lhlhlh lhllhh *h***l * l * * * * blank (see note.) h h * * * * retains the display conditions of , , and 1 before le goes high. dp is not related. http://www.ia.omron.com/ 6 (c)copyright omron corporation 2007 all rights reserved.
m7e decimal display unit models with zero suppression (m7e-01drd2/m7e- 01dgd2) note: 1. input low for rbi when data "0" is displayed. rbi will go high in open mode and the zero suppression will function. 2. the display will go blank when the data input is "0" and the dp is off. * either high or low models with blanking (m7e-01drd2-b/m7e-01dgd2-b) note: rbi takes precedence over any input signal. * either high or low input out- put display condition connector pin no. cefghd i j terminal number 356784 9 10 terminal symbol le d c b a dp rbi rbo input signals lllllh l l 0 (see note 1.) llllhh * l 1 lllhlh * l 2 lllhhh * l 3 llhllh * l 4 llhlhh * l 5 llhhlh * l 6 l lhhhh * l 7 lhlllh * l 8 lhllhh * l 9 lhlhlh * l lhlhhh * l blank lhhllh * l blank lhhlhh * l blank lhhhlh * l blank lhhhhh * l blank l****l * l * l l l l h h h blank (see note 2.) h * * * * * * * retains the display conditions of a through d, and dp terminals before le goes high. rbi is not related. input display condition connector pin no. ciefghd terminal number 3956784 terminal symbol lerbidcbadp input signals lhllllh 0 lhlllhh 1 lhllhlh 2 lhl lhhh 3 lhlhllh 4 lhlhlhh 5 lhlhhlh 6 lhlhhhh 7 lhhlllh 8 lhhllhh 9 lhhlhlh lhhlhhh blank lhhhl lh blank lhhhlhh blank lhhhhlh blank lhhhhhh blank *h****l *l*****blank (see note.) hh*****retains the display conditions of a through d terminals before le goes high. dp is not related. http://www.ia.omron.com/ 7 (c)copyright omron corporation 2007 all rights reserved.
m7e block diagram note: the terminal numbers of the unit display unit are different from the terminal numbers of the connector. refer to terminal arrangements and functions on page 3 for details. r display unit decimal/hexadecimal display unit (single color) (dynamic output is available with the decimal display units only.) decimal display unit (two colors) note: the le terminal is incorporated only on dynamic output models. note: the r/g 2 terminal lights red when off and green when on. signal input circuit positive logic signal input circuit positive logic negative logic negative logic signal input circuit negative logic dynamic output dynamic output unit display unit note: circled numbers are the board terminal numbers. power supply input v 0 v switching regulator signal inputs input circuit/ driver circuit led display elements (see note.) power supply input v 0 v switching regulator signal inputs input circuit/ driver circuit led display elements power supply input v 0 v switching regulator signal inputs input circuit/ driver circuit led display elements signal input gnd 24 to 47 k 3.9 k custom ic signal input gnd 150 k 330 k signal input gnd 3.9 to 8.2 k 3.9 k +5 v custom ic signal input 27 k +5 v 680 k gnd signal input gnd 27 k 680 k custom ic +5 v signal input gnd 7.5 to 8.2 k 3.9 k +5 v signal input gnd 27 k 680 k custom ic +5 v v 0 v switching regulator led display elements (gnd) http://www.ia.omron.com/ 8 (c)copyright omron corporation 2007 all rights reserved.
m7e external connections refer to the terminal arrangement on page 3 and the block diagram on page 8 for external connections for each unit. example of connection to a plc. ? refer to the plc operation manual before connecting the plc. ? the number of wires can be reduced by using a plc with dynamic outputs. plc output unit (pnp transistor output) 0 v plc custom ic 0 v a to d, dp, le out00 to 15 plc output unit (npn transistor output) plc custom ic a to d, dp, le out00 to 15 static output unit 1. m7e-01 @@ p2 positive logic model use a pnp transistor output unit for the plc output unit. connected to c500-od212 transistor output unit 2. m7e-01 @@ n2 negative logic model use an npn transistor output unit for the plc output unit. connected to c500-od213 transistor output unit http://www.ia.omron.com/ 9 (c)copyright omron corporation 2007 all rights reserved.
m7e plc dynamic output unit plc custom ic a to d, dp, le +24 vdc com (0 v) +24 vdc data0 to 7 stb0 to 7 12 to 24 vdc plc custom ic a to d, dp, le signal name pin no. data0 to 7 stb0 to 7 pull-up resistor: 2.0 to 3.9 k plc custom ic a to d, dp, le pull-up resistor plc dynamic output unit data0 to 7 stb0 to 7 using dynamic output units 1. m7e-01 @@ d2 dynamic output model 1. connected to c500-od211 transistor output unit 2. m7e-01 @@ p2 positive logic model an external pull-up resistor is required. connected to c500-od211 or c200h-od215 2. connected to c200-od215 transistor output unit note: 1. supply 24 vdc only. the plc does not operate with the m7e negative logic model. 2. the resistance of the pull- up resistor is 2.0 to 3.9 k : (1 w). a resistance of 3.3 k : is recommended. note: 1. when using the c200h- od215, the selector on the rear cover of the c200h-od215 must be set as follows: 2. refer to the c200h high- density i/o unit operation manual for the c200h-od215 and refer to the hardware section of the c500 operation manual for the c500-od211. sw1 (dynamic output mode) on sw2 off sw3 off sw4 off sw5 (positive logic output) on sw6 off http://www.ia.omron.com/ 10 (c)copyright omron corporation 2007 all rights reserved.
m7e operation operation timing (input signal timing) operation chart pulse duration (tw) 1.5 ms min. hold time (th) 0.75 ms min. setup time (ts) 2.25 ms min. ts tw th data latch data input signals a to d latching input le t w: pulse duration t h: hold time t s: setup time data latch data read h l ts tw th h l data latch data input signals a to d latching input le t w: pulse duration t h: hold time t s: setup time data latch data read positive logic negative logic the "1 " display is turned off by the le signal. the "5 " display is turned off by the le signal. ? the following example shows the relationship between each input terminal signal and the display condition for a negative-logic decimal display unit with blanking. data te r m i n a l displayed value 0123456789 description input signals a (2 0 ) h l inputs the data signal as bcd (or binary code). b (2 1 ) h l c (2 2 ) h l d (2 3 ) h l dp h l low when the decimal point lights. le h l low when all the display turns off. (high is maintained until the signal goes low.) display condition --- remarks --- data read data latch data latch data latch data latch data latch data latch data read data read data read ? u s i ng t h e l atc hi nput (le) term i na lf or eac hu n i t, t h e d ata i nput term i na l s (a to d) can b e use di n common yet st ill ena bl e di sp l ay on eac hu n i t (example of a 3-digit dynamic-output model with positive logic). data input signals (a to d) 0 (power: on) 5 7 6 1 latch input sig- nals 3 rd digit (le3) h l 2 nd digit (le2) h l 1 st digit (le1) h l display condition 3 rd -digit display change 2 nd -digit display change 1 st -digit display change 3 rd -digit display change a numeric value is displayed one digit at a time via data signals a to d. 3 rd digit data input signals le3 latch input signal (third digit) 2 nd digit le2 latch input signal (second digit) le1 latch input signal (first digit) 1 st digit http://www.ia.omron.com/ 11 (c)copyright omron corporation 2007 all rights reserved.
m7e example of zero suppression usage: description using negative logic model the zero suppression function operates when the display is 0 , rbi is low and the decimal point is not lit. example 1: the rbi input and rbo output of each digit are open when zero suppression is not being used. example 2: wired as shown to display only 0 for the rightmost digit when zero suppression is being used. example 3: zeros are suppressed only for the digits on the left of the digit where the decimal is lit when both zero suppression and a decimal point are being used. example 4: zeros are suppressed to the right of the first digit below the decimal point when both zero suppression and a decimal point are being used. if the first-to-fourth-digit values are all 0 and the decimal point is lit at the fourth digit, 0.0 @@ will be displayed. (there is no data in @@ .) note: use rbo output for the rbi input connection only. dimensions note: all units are in millimeters unless otherwise indicated. example 1 example 2 example 3 example 4 4 th digit 3 rd digit 2 nd digit 1 st digit 14.2 (15.2) 10 (8) 7.8 (8.8) 30 33.5 3 43 20 66 20 20 b-1 4.5 4.5 6.1 1 20 a (39) 33 b 31 0 ?0.4 m7e-01 @@@@ 2 values in parentheses are for the two-color (red and green) digital display units. led (unit: mm) note: 1. dimensions a and b include end plates. inclusion of spacers increases the length by 10 mm per spacer. 2. to l e r a n c e i s r 0.4 mm unless otherwise specified. number of units (n) dimensions a (n20+12) dimensions b (n20+10) 1 2 3 4 5 6 7 8 32 r 0.4 52 r 0.4 72 r 0.4 92 r 0.4 112 r 0.8 132 r 0.8 152 r 0.8 172 r 0.8 30 r 0.4 50 r 0.4 70 r 0.4 90 r 0.4 110r 0.8 130r 0.8 150r 0.8 170r 0.8 panel cutout panel thickness: 1 to 3 mm http://www.ia.omron.com/ 12 (c)copyright omron corporation 2007 all rights reserved.
m7e accessories (order separately) face plate ? the required face plate is used with the unit display unit, which incorporates a surface-lighting led. ? the following face plates are available. when ordering the m7e-01u @ 2- , add the suffix according to your requirement. ? custom face plates can be made. for the procedure to make face plates, refer to safety precautions for m7e . 30 33.5 (39) 33 6 (4.3) 4.5 4.5 4 30 33.5 (39) 33 6 (4.3) 4.5 end plate m7e-012m(-1) left end right end note: tolerance is r 0.4 mm unless otherwise specified. 30 33.5 4 4.5 10 25 (39) 33 spacer m7e-012pa(-1) 6 9 31 10 11 2 up 531 6 7 8 9 10 11 42 up 531 6 7 8 9 10 11 42 up 30.2 0.1 two, 3.3 dia. 20.5 13.5 9 p=2.54 25.4 0.2 32 3 0.15 34 42 0.15 48 7.8 0 ?0.1 30 7.8 32 34 20.5 13.5 9 p=2.54 25.4 0.2 3 0.15 1 2 elliptical hole +0 ?0.3 +0.3 0 30.2 0.1 25.4 0.2 7.8 32 34 17.5 0.6 0.6 13.5 9 p=2.54 25.4 0.2 3 0.15 0 ?0.1 connector nrt-c soldered terminal nrt-cn soldered terminal nrt-cp pcb terminal symbolabcdefghjjc1kvz1z2 display contents @ blank display in the interest of product improvement, specifications are subject to change without notice. all dimensions shown are in millimeters. to convert millimeters into inches, multiply by 0.03937. to convert grams into ounces, multiply by 0.03527. http://www.ia.omron.com/ 13 (c)copyright omron corporation 2007 all rights reserved.
safety precautions for m7e precautions for correct use display units installation environment ? use the unit in locations that are not subject to organic solvents (thinner, benzene, etc.), strong alkali, strong acid, sunlight, and corrosive gases. ? these display units are designed for indoor use only. visibility may be significantly reduced if the unit is used outside or in locations where the ambient brightness exceeds the brightness of the m7e. the product is not drip-proof. use the product where it will not be subject to water or oil splashing. ? use the units in areas not subject to vibration or shock in excess of specifications. mounting connector insertion when inserting the connector, make sure that the up arrow is pointing upwards. ? when the end plates are linked, the entire set can be quickly mounted and fastened to a panel. confirm that the links between units and end plates are secure, and then securely fasten the end plate tips to the panel. wiring and connections make sure that no wire is more than five meters long when wiring. handling there are projecting tips made of resin on the side of each display unit. be sure not to drop the display unit, otherwise the projecting tips may break. procedure for making face plates for m7e-01 unit display unit custom face plates can be made according to the following guidelines. 1. prepare a blank unit display unit (m7e-01ur2-a or m7e- 01ug2-a) for the desired lighting color. 2. take transparent polyester film (with thickness equivalent to 0.188) and cut it to the following dimensions. 3. print solid black on the film covering all areas except the character and so that the desired unit character is within the character display range (with the unit character transparent). 4. install the completed face plate into the unit display unit. mother board wiring and connections secure the cable and lead wires with the panel so that no excessive force will be imposed on the input connector or power supply terminals. ? link the units by snapping the projecting tips and slots together. ? to undo the linkage, use a slotted screwdriver as shown in the following figure and press the upper and lower tips while separating. projecting tip slot connector panel face plate dimensions 18.6 0 ?0.3 31 0 ?0.3 5 7 11 character display range face plate dimensions character display range face plate now completed (not included with the m7e-01u@2-a) surface-lighting led (red) filter http://www.ia.omron.com/ c-1 (c)copyright omron corporation 2007 all rights reserved.
m7e connection ? connection of mother board and m7e note: do not connect the mother board static model to the m7e- 01d @ d2(-b) dynamic model, otherwise le will be held. ? when using the m7e-01 @@ p2(-b) positive logic standard model, a pullup resistor may be required. check the output circuit of the connecting device and use a pull-up resistor if necessary. ? all m7e models used on a single mother board must be identical. connecting or disconnecting the m7e when connecting the m7e to or disconnecting the m7e from the mother board, hold the front panel of the m7e or the case and be sure to apply appropriate force on the top and bottom of the mother board alternately. mother board positive negative dynamic static ??u (see note.) ? : possible u : impossible dynamic ??? hold panel mother board hold hold in the interest of product improvement, specifications are subject to change without notice. all dimensions shown are in millimeters. to convert millimeters into inches, multiply by 0.03937. to convert grams into ounces, multiply by 0.03527. http://www.ia.omron.com/ c-2 (c)copyright omron corporation 2007 all rights reserved.
2007. 10 omron corporation industrial automation company http://www.ia.omron.com/ (c)copyright omron corporation 2007 all rights reserved. in the interest of product improvement, specifications are subject to change without notice. read and understand this catalog please read and understand this catalog before purchasing the products. please consult your omron representative if you have an y questions or comments. warranty and limitations of liability warranty omron's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if speci ed) from date of sale by omron. omron makes no warranty or representation, express or implied, regarding non-infringement, merchantability, or fitness for particular purpose of the products. any buyer or user acknowledges that the buyer or user alone has determined that the products will suitably meet the requirements of their intended use. omron disclaims all other warranties, express or implied. limitations of liability omron shall not be responsible for special, indirect, or consequential damages, loss of profits, or commercial loss in any way connected with the products, whether such claim is based on contract, warranty, negligence, or strict liability. in no event shall responsibility of omron for any act exceed the individual price of the product on which liability is asserted . in no event shall omron be responsible for warranty, repair, or other claims regarding the products unless omron's analysis confirms that the products were properly handled, stored, installed, and maintained and not subject to contamination, abuse, misuse, or inappropriate modification or repair. application considerations suitability for use omron shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the product. at the customer's request, omron will provide applicable third party certi cation documents identifying ratings and limitations of use that apply to the products. this information by itself is not suf cient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. the following are some examples of applications for which particular attention must be given. this is not intended to be an exh austive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: ? outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. ? nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. ? systems, machines, and equipment that could present a risk to life or property. please know and observe all prohibitions of use applicable to the products. never use the products for an application involving serious risk to life or property without ensuring that the system as a whole has been designed to address the risks, and that the omron product is properly rated and installed for the intended use within the overall equipment or system. disclaimers change in specifications product speci cations and accessories may be changed at any time based on improvements and other reasons. it is our practice to change model numbers when published ratings or features are changed, or when signi cant construction changes are made. however, some speci cations of the product may be changed without any notice. when in doubt, special model numbers may be assigned to x or establish key speci cations for your application on your request. please consult with your omron representative at any time to con rm actual speci cations of purchased product. dimensions and weights dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. errors and omissions the information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assume d for clerical, typographical, or proofreading errors, or omissions. performance data performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. it may represent the result of omron?s test conditions, and the users must correlate it to actual application requirements. actual performance is subject to the omron warranty and limitations of liability. programmable products omron shall not be responsible for the user's programming of a programmable product, or any consequence thereof. copyright and copy permission this catalog shall not be copied for sales or promotions without permission. this catalog is protected by copyright and is intended solely for use in conjunction with the product. please notify us before copying or reproducing this catalog in any manner, for any other purpose. if copying or transmitting this catalog to another, please copy or transmit it in its entirety.


▲Up To Search▲   

 
Price & Availability of M7E-01HRP2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X